| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Full paper |
1 Departments of Diagnostic Imaging 2 Clinical Physics 3 Otolaryngology, St Bartholomew's Hospital, West Smithfield, London EC1A 7BE, UK
The aim of this study was to determine the effect of reducing mAs on the diagnostic quality of images and the radiation dose to the orbits in patients undergoing sinus CT. We studied 40 consecutive patients undergoing paranasal sinus CT for inflammatory disease prior to functional endoscopic sinus surgery (FESS). Four groups of 10 patients were scanned at 200 mAs, 150 mAs, 100 mAs and 50 mAs, respectively. Orbital radiation dose was measured using thermoluminescent dosemeters. Images were reviewed independently by two observers who were unaware of the mAs setting used. Image quality was evaluated using a semi-quantitative scoring system for six anatomical structures. The osteomeatal complex, uncinate process, infundibulum, frontal recess, middle turbinate and optic nerve were assessed as: clearly demonstrated (2 points); demonstrated but not clearly visualized (1 point); or not seen (0 points). No significant difference was shown between any of the four groups in terms of image quality according to the scoring system used in this study. Mean radiation dose to the orbit was reduced by 77%, from 13.5 mGy at 200 mAs to 3.1 mGy at 50 mAs (p<0.05). CT of the sinuses can be performed in patients prior to FESS at greatly reduced mAs without loss of diagnostic quality of the images. This is important in reducing the radiation dose to the lens.
This article has been cited by other articles:
![]() |
E.J. Lee, S.K. Lee, R. Agid, P. Howard, J.M. Bae, and K. terBrugge Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography AJNR Am. J. Neuroradiol., October 1, 2009; 30(9): 1754 - 1759. [Abstract] [Full Text] [PDF] |
||||
![]() |
C.B. Nauer, A. Eichenberger, P. Dubach, J. Gralla, and M. Caversaccio CT Radiation Dose for Computer-Assisted Endoscopic Sinus Surgery: Dose Survey and Determination of Dose-Reduction Limits AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 617 - 622. [Abstract] [Full Text] [PDF] |
||||
![]() |
R Olszewski, H Reychler, G Cosnard, J M Denis, S Vynckier, and F Zech Accuracy of three-dimensional (3D) craniofacial cephalometric landmarks on a low-dose 3D computed tomograph Dentomaxillofac. Radiol., July 1, 2008; 37(5): 261 - 267. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Brem, A. A. Zamani, R. Riva, K. H. Zou, Z. Rumboldt, F. F. Hennig, R. Kikinis, A. M. Norbash, and U. J. Schoepf Multidetector CT of the Paranasal Sinus: Potential for Radiation Dose Reduction Radiology, June 1, 2007; 243(3): 847 - 852. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. V. Sahani, S. P. Kalva, P. F. Hahn, and S. Saini 16-MDCT Angiography in Living Kidney Donors at Various Tube Potentials: Impact on Image Quality and Radiation Dose Am. J. Roentgenol., January 1, 2007; 188(1): 115 - 120. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. H. Mulkens, C. Broers, S. Fieuws, J.-L. Termote, and P. Bellnick Comparison of Effective Doses for Low-Dose MDCT and Radiographic Examination of Sinuses in Children Am. J. Roentgenol., May 1, 2005; 184(5): 1611 - 1618. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. B. Ertl-Wagner, R.-T. Hoffmann, R. Bruning, K. Herrmann, B. Snyder, J. D. Blume, and M. F. Reiser Multi-Detector Row CT Angiography of the Brain at Various Kilovoltage Settings Radiology, May 1, 2004; 231(2): 528 - 535. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Fox Use of the Lowest Necessary Radiation Dose AJNR Am. J. Neuroradiol., April 1, 2004; 25(4): 519 - 519. [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, T. L. Toth, L. M. Hamberg, M. A. Blake, J.-A. Shepard, and S. Saini Strategies for CT Radiation Dose Optimization Radiology, March 1, 2004; 230(3): 619 - 628. [Abstract] [Full Text] [PDF] |
||||
![]() |
I Zammit-Maempel, C L Chadwick, and S P Willis Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT Br. J. Radiol., June 1, 2003; 76(906): 418 - 420. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, S. Prasad, S. Saini, M. A. Blake, J. Varghese, E. F. Halpern, J. T. Rhea, and J. H. Thrall Clinical Comparison of Standard-Dose and 50% Reduced--Dose Abdominal CT: Effect on Image Quality Am. J. Roentgenol., November 1, 2002; 179(5): 1101 - 1106. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. R. Prasad, C. Wittram, J.-A. Shepard, T. McLoud, and J. Rhea Standard-Dose and 50%--Reduced-Dose Chest CT: Comparing the Effect on Image Quality Am. J. Roentgenol., August 1, 2002; 179(2): 461 - 465. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |