| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Full paper |
1 Medical Physics Group, Radiology Department, Complutense University, 28040 Madrid
2 3, Ricardo de la Vega St., 28901 Getafe, Spain
Correspondence: Prof. L González, Catedra de Fisica Medica, Facultad de Medicina, Universidad Complutense, 28040 Madrid, Spain
The present work describes an experiment undertaken using thermoluminescent dosemeters to obtain a local reference dose level in orthopantomography, based on patient measurements in 11 dentistry installations. In addition, a critical audit of the dose recommended by the International Atomic Energy Agency for intraoral X-ray diagnostics is performed, based on data gathered from over 300 intraoral X-ray facilities. The provisional local reference levels proposed are 0.7 mGy entrance surface dose at the occipital region for orthopantomography and 3.5 mGy entrance surface dose for intraoral radiology.