Impact of motion artefact on the measurement of coronary calcium score

SJ Brown, MP Hayball and RA Coulden
Department of Radiology, Papworth Hospital NHS Trust, Cambridge, UK.

Reports have shown that total coronary calcium (CC) measured by electron beam CT (EBCT) correlates well with atheroma extent, and this in turn is a reliable indicator of risk for future ischaemic events. Although total CC may be measured using a conventional CT scanner, image quality is degraded by cardiac motion artefact. Errors in CC measurement owing to slice misregistration between adjacent breath-holds affect both conventional CT and EBCT. The latest generation conventional CT scanners have acquisition times of 500 ms or shorter, and, when combined with ECG triggering, quantitative CC measurement without reliance upon EBCT becomes a real possibility. We investigated the effect of motion on the measured calcium score using a moving phantom. Our results show that use of ECG triggering with conventional CT improves reproducibility of Agatston calcium score measurement. Increasing motion time during image acquisition results in an apparent increase in the Agatston CC score. Alternative measures of the amount of CC may be less susceptible to motion-induced bias, but have a similar reproducibility.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. M. Kim, M. J. Chung, K. S. Lee, Y. H. Choe, C. A. Yi, and B.-K. Choe
Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction
Am. J. Roentgenol., April 1, 2008; 190(4): 917 - 922.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Vliegenthart, B. Song, A. Hofman, J. C. M. Witteman, and M. Oudkerk
Coronary Calcification at Electron-Beam CT: Effect of Section Thickness on Calcium Scoring in Vitro and in Vivo
Radiology, November 1, 2003; 229(2): 520 - 525.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Takahashi and K. T. Bae
Quantification of Coronary Artery Calcium with Multi-Detector row CT: Assessing Interscan Variability with Different Tube Currents—Pilot Study
Radiology, July 1, 2003; 228(1): 101 - 106.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2000 by the British Institute of Radiology.