| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
The British Journal of Radiology, Vol 73, Issue 873 1002-1006, Copyright © 2000 by British Institute of Radiology
ARTICLES |
JR Williams and A Montgomery
Department of Medical Physics and Medical Engineering, Western General Hospital, Edinburgh, UK.
The National Radiological Protection Board (NRPB) has recommended the introduction of dose-width product (DWP) for the measurement of patient dose in panoramic dental radiology and has proposed a reference level of 65 mGy mm for adult exposures. This paper describes a method for measuring DWP and dose-area product (DAP) using thermoluminescent dosemeters (TLDs). The technique was used on 16 sets with a range of exposure settings. The mean value of DWP was 14% higher than the mean value reported from a survey by the NRPB. This difference is most likely to be caused by systematic variations due to measurement method. The average DAP for a standard adult examination was shown to be 11.3 cGy cm2. Data are presented so that the DAP can be derived from the exposure factors (tube current and operating potential) and beam area. Based on published data for effective dose, it is estimated that the DAP to effective dose conversion factor is approximately 0.06 mSv(Gy cm2)-1. The average DAP value (11.3 cGy cm2) can be compared with the average value for intraoral radiography (9.3 cGy cm2) based on the NRPB survey of entrance surface doses assuming 6 cm circular collimation.
This article has been cited by other articles:
![]() |
H. K. Looe, F. Eenboom, N. Chofor, A. Pfaffenberger, M. Steinhoff, A. Ruhmann, A. Poplawski, K. Willborn, and B. Poppe Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product values Radiat Prot Dosimetry, September 1, 2008; 131(3): 365 - 373. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog Radiology, July 1, 2008; 248(1): 254 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Martin RADIATION DOSIMETRY FOR DIAGNOSTIC MEDICAL EXPOSURES Radiat Prot Dosimetry, March 28, 2008; (2008) ncm495v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Lofthag-Hansen, A Thilander-Klang, A Ekestubbe, E Helmrot, and K Grondahl Calculating effective dose on a cone beam computed tomography device: 3D Accuitomo and 3D Accuitomo FPD Dentomaxillofac. Radiol., February 1, 2008; 37(2): 72 - 79. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Connor, T Arscott, J Berry, L Greene, and R O'Gorman Precision and accuracy of low-dose CT protocols in the evaluation of skull landmarks Dentomaxillofac. Radiol., July 1, 2007; 36(5): 270 - 276. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Poppe, H. K. Looe, A. Pfaffenberger, N. Chofor, F. Eenboom, M. Sering, A. Ruhmann, A. Poplawski, and K. Willborn Dose-area product measurements in panoramic dental radiology Radiat Prot Dosimetry, January 1, 2007; 123(1): 131 - 134. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Doyle, C J Martin, and J Robertson Techniques for measurement of dose width product in panoramic dental radiography Br. J. Radiol., February 1, 2006; 79(938): 142 - 147. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Helmrot and G. Alm Carlsson Measurement of radiation dose in dental radiology Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 168 - 171. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Gijbels, R Jacobs, R Bogaerts, D Debaveye, S Verlinden, and G Sanderink Dosimetry of digital panoramic imaging. Part I: patient exposure Dentomaxillofac. Radiol., May 1, 2005; 34(3): 145 - 149. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. E. Tierris, E. N. Yakoumakis, G. N. Bramis, and E. Georgiou Dose area product reference levels in dental panoramic radiology Radiat Prot Dosimetry, October 11, 2004; 111(3): 283 - 287. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Aroua, I Buchillier-Decka, K Dula, Y Nedjadi, M Perrier, J-P Vader, and J-F Valley Radiation exposure in dental radiology: a 1998 nationwide survey in Switzerland Dentomaxillofac. Radiol., July 1, 2004; 33(4): 211 - 219. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Isoardi and R Ropolo Measurement of dose-width product in panoramic dental radiology Br. J. Radiol., February 1, 2003; 76(902): 129 - 131. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |