BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crawley, M. T.
Right arrow Articles by Rogers, A. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Crawley, M. T.
Right arrow Articles by Rogers, A. T.

The British Journal of Radiology, Vol 73, Issue 871 740-744, Copyright © 2000 by British Institute of Radiology


ARTICLES

Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels

MT Crawley and AT Rogers
Stoke Mandeville Hospital NHS Trust, Aylesbury, Buckinghamshire, UK.

There is a national drive towards establishing reference doses for radiological procedures with the aim of optimizing patient doses. Furthermore, the establishment of diagnostic reference level doses became a legal requirement for all hospitals on 13 May 2000. However, to date there are little published data on patient radiation doses from fluoroscopic procedures during orthopaedic surgery. Data relating to patient dose for 492 patients undergoing fluoroscopic examinations during a range of surgical orthopaedic procedures in 1997-1998 have been analysed. Median dose-area product (DAP) readings and interquartile ranges for a variety of common fluoroscopic orthopaedic procedures are presented. In general, the median DAP for procedures on limbs and extremities was quite low (0.04-1.62 Gy cm2), with screening times in the range 0.2-2.0 min, whilst for procedures involving the hips and spine the median DAP was considerably higher (0.4-10.2 Gy cm2), although overall screening times were similar, in the range 0.2-1.4 min. Approximate effective doses have been estimated. For procedures involving the limbs and extremities, the effective dose was generally less than 10 microSv, and for procedures involving the hips and spine it was found that the effective dose could rise to about 1 mSv. Collective doses for each procedure have been calculated to inform prioritization of procedures for local dose reduction strategies.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
A. Pillai, A. McAuley, K. McMurray, and M. Jain
Fluroscopy in paediatric fractures--setting a local diagnostic reference level
Radiat Prot Dosimetry, December 1, 2006; 121(2): 186 - 190.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Perisinakis, J. Damilakis, N. Theocharopoulos, G. Papadokostakis, A. Hadjipavlou, and N. Gourtsoyiannis
Patient effective dose and radiogenic risks from fluoroscopically assisted surgical reconstruction of femoral fractures
Radiat Prot Dosimetry, January 1, 2004; 108(1): 65 - 72.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2000 by the British Institute of Radiology.