The British Journal of Radiology, Vol 73, Issue 869 517-530, Copyright © 2000 by British Institute of Radiology


ARTICLES

Dosimetric properties of the Theraview fluoroscopic electronic portal imaging device

AG Glendinning and DE Bonnett
Department of Medical Physics, Leicester Royal Infirmary NHS Trust, UK.

Electronic portal imaging devices (EPIDs) can be used for non-imaging applications in radiotherapy such as patient dosimetry. Of the systems available, the fluoroscopic camera-based EPID Theraview (InfiMed Inc.) has not been studied to date, and a review of the dosimetric properties of the system is presented here. In the "single set-up" mode of image acquisition, pixel intensity increases sublinearly with applied dose. The response was dependent on the system's video signal gain and showed a threshold dose to the detector in the range 0.05-0.35 cGy, and pixel saturation at detector doses in the range 1.2-1.6 cGy. Repeated exposures of the EPID were observed to be extremely reproducible (standard deviation 0.5%). The sensitivity of the system showed a linear decline of 0.04% day-1 over a 68-day period, during which time the relative off-axis response within 10 x 10 cm2 field was constant to within a standard deviation of 0.56%. The system shows spatial non-uniformity, which requires correction for application to dose measurements in two-dimensions. Warm-up of the camera control unit required a period of at least 40 min and was associated with an enhancement in pixel intensity of up to 12%. A radiation dose history effect was observed at doses as low as 0.2 Gy. Camera dark current was shown to be negligible at normal accelerator operation. No discernible image distortion was found. Mechanical stability on gantry rotation was also assessed and image displacement of up to 5 mm at the isocentre was observed. It was concluded that the device could be used for dosimetry provided necessary precautions were observed and corrections made.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
M C Kirby and A G Glendinning
Developments in electronic portal imaging systems
Br. J. Radiol., September 1, 2006; 79(Special_Issue_1): S50 - S65.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K A Langmack
Portal imaging
Br. J. Radiol., September 1, 2001; 74(885): 789 - 804.
[Abstract] [Full Text] [PDF]