BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nicholson, R.
Right arrow Articles by Uthappa, M. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nicholson, R.
Right arrow Articles by Uthappa, M. C.

The British Journal of Radiology, Vol 73, Issue 865 36-42, Copyright © 2000 by British Institute of Radiology


ARTICLES

Skin sparing in interventional radiology: the effect of copper filtration

R Nicholson, F Tuffee and MC Uthappa
Department of Radiology, St Mary's Hospital, London, UK.

Complex and lengthy interventional radiological techniques have resulted in a number of patients developing skin reactions in recent years. To safeguard against these side effects, we have investigated the degree to which entrance skin dose can be reduced by inserting 0.18 mm and 0.35 mm copper filtration in the incident beam. The potential reduction was measured on a 22 cm water phantom for each of eight models of a fluoroscopy unit. Using the catheter laboratory fluoroscopy unit on which radiofrequency ablations are routinely performed, we assessed the relative effectiveness of adding filtration and increasing the kV:mA ratio. Image quality was subjectively assessed for diagnostic and therapeutic acceptability in two groups of 10 patients undergoing radiofrequency ablations, pacemaker insertions or electrophysiology studies. One of the groups was screened with 0.35 mm copper filtration in place and the other group acted as the control. Maximum patient skin dose proved difficult to measure directly because of the unpredictable dose pattern. This pattern was studied in four patients using a film method in conjunction with thermoluminescent dosemeters. Copper filtration 0.35 mm thick inserted in the beams of the eight fluoroscopy units produced a mean reduction in entrance dose to the phantom of 58% with a mean increase in tube loading of 29%. At 100 kV the increased loading on the X-ray tube was equivalent to increasing the anteroposterior separation of the patient by 2 cm. Measurements on the catheter laboratory unit showed that the tube voltage would need to be raised above the normal diagnostic range to obtain an equivalent entrance dose reduction without the filter. The blackening of films under the patients showed complex patterns, but the estimated skin doses were consistent with those predicted by the phantom experiments. All six cardiologists considered there to be insignificant detriment to image quality in the procedures investigated.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
V TSAPAKI, P N MANIATIS, A MAGGINAS, V VOUDRIS, S PATSILINAKOS, T VRANZTA, E VANO, and D S COKKINOS
What are the clinical and technical factors that influence the kerma-area product in percutaneous coronary intervention?
Br. J. Radiol., December 1, 2008; 81(972): 940 - 945.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D G W Onnasch, A Schemm, and H-H Kramer
Optimization of radiographic parameters for paediatric cardiac angiography
Br. J. Radiol., June 1, 2004; 77(918): 479 - 487.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. L. Miller, S. Balter, P. T. Noonan, and J. D. Georgia
Minimizing Radiation-induced Skin Injury in Interventional Radiology Procedures
Radiology, November 1, 2002; 225(2): 329 - 336.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. Mahesh
Fluoroscopy: Patient Radiation Exposure Issues
RadioGraphics, July 1, 2001; 21(4): 1033 - 1045.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 2000 by the British Institute of Radiology.