BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robinson, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Robinson, P. J.

The British Journal of Radiology, Vol 70, Issue 839 1085-1098, Copyright © 1997 by British Institute of Radiology


ARTICLES

Radiology's Achilles' heel: error and variation in the interpretation of the Rontgen image

PJ Robinson
Department of Clinical Radiology, St James's University Hospital, Leeds, UK.

The performance of the human eye and brain has failed to keep pace with the enormous technical progress in the first full century of radiology. Errors and variations in interpretation now represent the weakest aspect of clinical imaging. Those interpretations which differ from the consensus view of a panel of "experts" may be regarded as errors; where experts fail to achieve consensus, differing reports are regarded as "observer variation". Errors arise from poor technique, failures of perception, lack of knowledge and misjudgments. Observer variation is substantial and should be taken into account when different diagnostic methods are compared; in many cases the difference between observers outweighs the difference between techniques. Strategies for reducing error include attention to viewing conditions, training of the observers, availability of previous films and relevant clinical data, dual or multiple reporting, standardization of terminology and report format, and assistance from computers. Digital acquisition and display will probably not affect observer variation but the performance of radiologists, as measured by receiver operating characteristic (ROC) analysis, may be improved by computer-directed search for specific image features. Other current developments show that where image features can be comprehensively described, computer analysis can replace the perception function of the observer, whilst the function of interpretation can in some cases be performed better by artificial neural networks. However, computer-assisted diagnosis is still in its infancy and complete replacement of the human observer is as yet a remote possibility.


This article has been cited by other articles:


Home page
RadiologyHome page
C. G. Filippi, B. Schneider, H. N. Burbank, G. F. Alsofrom, G. Linnell, and B. Ratkovits
Discrepancy Rates of Radiology Resident Interpretations of On-Call Neuroradiology MR Imaging Studies
Radiology, December 1, 2008; 249(3): 972 - 979.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. D. Johnson, J. G. Fletcher, R. L. MacCarty, J. N. Mandrekar, W. S. Harmsen, P. J. Limburg, and L. A. Wilson
Effect of Slice Thickness and Primary 2D Versus 3D Virtual Dissection on Colorectal Lesion Detection at CT Colonography in 452 Asymptomatic Adults
Am. J. Roentgenol., September 1, 2007; 189(3): 672 - 680.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S Brealey and M Westwood
Are you reading what we are reading? The effect of who interprets medical images on estimates of diagnostic test accuracy in systematic reviews
Br. J. Radiol., August 1, 2007; 80(956): 674 - 677.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S D Brealey, A J Scally, S Hahn, and C Godfrey
Evidence of reference standard related bias in studies of plain radiograph reading performance: a meta-regression
Br. J. Radiol., June 1, 2007; 80(954): 406 - 413.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Berlin
Accuracy of Diagnostic Procedures: Has It Improved Over the Past Five Decades?
Am. J. Roentgenol., May 1, 2007; 188(5): 1173 - 1178.
[Full Text] [PDF]


Home page
jvmeHome page
C.R. Lamb, D.U. Pfeiffer, and P. Mantis
Errors in Radiographic Interpretation Made by Veterinary Students
J Vet Med Educ, January 1, 2007; 34(2): 157 - 159.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
G. Bernardi, R. Padovani, W. Desmet, A. Peterzol, J. D. Giannuleas, E. Neofotistou, A. Manginas, Z. Olivari, J. Cosgrave, F. Alfonso, et al.
A Study to validate the method based on DIMOND quality criteria for cardiac angiographic images
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 263 - 268.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Tingberg, F. Eriksson, J. Medin, J. Besjakov, M. Bath, M. Hakansson, M. Sandborg, A. Almen, B. Lanhede, G. Alm-Carlsson, et al.
Inter-observer variation in masked and unmasked images for quality evaluation of clinical radiographs
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 62 - 68.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. N. Buchanan, S. Halligan, S. Taylor, A. Williams, R. Cohen, and C. Bartram
MRI of Fistula In Ano: Inter- and Intraobserver Agreement and Effects of Directed Education
Am. J. Roentgenol., July 1, 2004; 183(1): 135 - 140.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Ward, M. B. Sheridan, J. A. Guthrie, M. H. Davies, C. E. Millson, J. P. A. Lodge, S. G. Pollard, K. R. Prasad, G. J. Toogood, and P. J. Robinson
Bile Duct Strictures after Hepatobiliary Surgery: Assessment with MR Cholangiography
Radiology, April 1, 2004; 231(1): 101 - 108.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
T. P. Hofer and R. A. Hayward
Are Bad Outcomes from Questionable Clinical Decisions Preventable Medical Errors? A Case of Cascade Iatrogenesis
Ann Intern Med, September 3, 2002; 137(5_Part_1): 327 - 333.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. S. Yoon, A. H. Haims, J. A. Brink, R. Rabinovici, and H. P. Forman
Evaluation of an Emergency Radiology Quality Assurance Program at a Level I Trauma Center: Abdominal and Pelvic CT Studies
Radiology, July 1, 2002; 224(1): 42 - 46.
[Abstract] [Full Text]


Home page
Br. J. Radiol.Home page
S Brealey, A J Scally, and N B Thomas
Methodological standards in radiographer plain film reading performance studies
Br. J. Radiol., February 1, 2002; 75(890): 107 - 113.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
T. V Nguyen, K. M Hillman, M. D Buist, S Chakraverty, J Wright, R. Plowman, J. A Roberts, N. Graves, M. A S Griffin, B. Cookson, et al.
Adverse events in British hospitals
BMJ, June 9, 2001; 322(7299): 1425 - 1425.
[Full Text]


Home page
Br. J. Radiol.Home page
S Brealey and A J Scally
Bias in plain film reading performance studies
Br. J. Radiol., April 1, 2001; 74(880): 307 - 316.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Lucaya, J. Piqueras, P. Garcia-Pena, G. Enriquez, M. Garcia-Macias, and J. Sotil
Low-Dose High-Resolution CT of the Chest in Children and Young Adults: Dose, Cooperation, Artifact Incidence, and Image Quality
Am. J. Roentgenol., October 1, 2000; 175(4): 985 - 992.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Bartram, S. Halligan, J. Stoker, E. Rociu, and J. S. Laméris
Endoanal MR Is Really Complementary to Endoanal US Dr Stoker and colleagues respond:
Radiology, September 1, 2000; 216(3): 918 - 920.
[Full Text]


Home page
Eur Heart JHome page
R Brennecke, U Burgel, R Simon, G Rippin, H.P Fritsch, T Becker, and S.E Nissen
American College of Cardiology/ European Society of Cardiology international study of angiographic data compression phase III. Measurement of image quality differences at varying levels of data compression
Eur. Heart J., April 2, 2000; 21(8): 687 - 696.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
R.u. Brennecke, U. Burgel, R.u. Simon, G. Rippin, H. P. Fritsch, T. Becker, and S. E. Nissen
American College of Cardiology/ European Society of Cardiology international study of angiographic data compression phase III: Measurement of image quality differences at varying levels of data compression
J. Am. Coll. Cardiol., April 1, 2000; 35(5): 1388 - 1397.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
S. W. Rathbun, G. E. Raskob, and T. L. Whitsett
Sensitivity and Specificity of Helical Computed Tomography in the Diagnosis of Pulmonary Embolism: A Systematic Review
Ann Intern Med, February 1, 2000; 132(3): 227 - 232.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. D. Tourassi
Journey toward Computer-aided Diagnosis: Role of Image Texture Analysis
Radiology, November 1, 1999; 213(2): 317 - 320.
[Full Text]


Home page
JCOHome page
B. D. Fletcher, A. S. Glicksman, and P. Gieser
Interobserver Variability in the Detection of Cervical-Thoracic Hodgkin's Disease by Computed Tomography
J. Clin. Oncol., July 1, 1999; 17(7): 2153 - 2153.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. B. Gunderman and J. M. Nyce
The Tyranny of Accuracy in Radiologic Education
Radiology, February 1, 2002; 222(2): 297 - 300.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.