BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Franken, N. A.
Right arrow Articles by Wondergem, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Franken, N. A.
Right arrow Articles by Wondergem, J.

The British Journal of Radiology, Vol 70, Issue 838 1004-1009, Copyright © 1997 by British Institute of Radiology


ARTICLES

Comparison of in vivo cardiac function with ex vivo cardiac performance of the rat heart after thoracic irradiation

NA Franken, JA Camps, FJ van Ravels, A van der Laarse, EK Pauwels and J Wondergem
Department of Clinical Oncology, University Hospital Leiden, The Netherlands.

The aim of the study was to compare in vivo cardiac function with ex vivo cardiac performance after local heart irradiation in the same rat. Left ventricular ejection fraction (LVEF) was measured in vivo by radionuclide ventriculography in Sprague-Dawley rats up to 16 months after a single dose of 20 Gy. Four days after in vivo measurements, cardiac performance was determined ex vivo, using the isolated working rat heart preparation. After irradiation, cardiac performance measured ex vivo deteriorated more rapidly than the in vivo measured LVEF. Within 4 months post-treatment, ex vivo cardiac output and stroke volume started to decrease and declined continuously throughout the observation period of 16 months. The reduction in stroke volume was already significant (p < 0.04) at 4 months post-treatment, whereas the decline in cardiac output was significant (p < 0.05) at 12 months post-treatment. In vivo, no change in LVEF was observed during the first 12 months post-treatment. Thereafter, LVEF decreased rapidly from 65 +/- 2% to 46 +/- 8% (p < 0.01), at 16 months post-treatment. Up to 12 months post-irradiation, LVEF was not correlated to ex vivo cardiac output. At 16 months post-treatment, when clinical symptoms of heart failure become evident, a positive relation between both parameters was found. The lack of correlation between the in vivo and ex vivo measurements of cardiac function during the first 12 months post-treatment might be explained by the involvement of compensatory mechanisms being operative in vivo to maintain sufficient cardiac output.


This article has been cited by other articles:


Home page
Cancer Res.Home page
A. Novakova-Jiresova, P. van Luijk, H. van Goor, H. H. Kampinga, and R. P. Coppes
Pulmonary Radiation Injury: Identification of Risk Factors Associated with Regional Hypersensitivity
Cancer Res., May 1, 2005; 65(9): 3568 - 3576.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.