| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
The British Journal of Radiology, Vol 70, Issue 837 933-936, Copyright © 1997 by British Institute of Radiology
ARTICLES |
KS Coakley, J Ratcliffe and J Masel
Department of Physical Sciences, Royal Brisbane Hospital, Australia.
The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 microSv per week and for hands from 40 to 210 microSv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.
This article has been cited by other articles:
![]() |
M Whitby and C J Martin Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern? Br. J. Radiol., May 1, 2003; 76(905): 321 - 327. [Abstract] [Full Text] [PDF] |
||||
![]() |
J M C Gallet and M H Reed Paediatric personnel extremity dose study Br. J. Radiol., March 1, 2002; 75(891): 249 - 252. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |