BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coakley, K. S.
Right arrow Articles by Masel, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coakley, K. S.
Right arrow Articles by Masel, J.

The British Journal of Radiology, Vol 70, Issue 837 933-936, Copyright © 1997 by British Institute of Radiology


ARTICLES

Measurement of radiation dose received by the hands and thyroid of staff performing gridless fluoroscopic procedures in children

KS Coakley, J Ratcliffe and J Masel
Department of Physical Sciences, Royal Brisbane Hospital, Australia.

The aim of this study was to confirm that the radiation doses received by attendants who manually restrain infants during fluoroscopic procedures are low. Doses to the hands and neck of three radiologists and three nurses performing or assisting at all the fluoroscopic procedures in a children's hospital were measured for 1 month using thermoluminescent dosemeters. All fluoroscopy on children at this hospital is performed without an antiscatter grid. Total doses for the neck ranged from 20 to 50 microSv per week and for hands from 40 to 210 microSv per week. These doses were shared by the three radiologists and the three nurses. Individual doses received per staff member are very small when compared with the doses received by interventional radiology staff. Doses received by staff in this study were of the order of 5% of the limit advised by the National Health and Medical Research Council of Australia (NHMRC) for radiation workers. Nurses received larger doses than radiologists and steps will be taken to reduce this dose further.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
M Whitby and C J Martin
Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?
Br. J. Radiol., May 1, 2003; 76(905): 321 - 327.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J M C Gallet and M H Reed
Paediatric personnel extremity dose study
Br. J. Radiol., March 1, 2002; 75(891): 249 - 252.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.