BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mountford, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mountford, P. J.

The British Journal of Radiology, Vol 70, Issue 835 671-684, Copyright © 1997 by British Institute of Radiology


ARTICLES

Risk assessment of the nuclear medicine patient

PJ Mountford
Department of Biomedical Engineering and Medical Physics, Royal Infirmary, Stoke-on-Trent, Staffordshire, UK.

Two types of risk are identified following the administration of a radiopharmaceutical to a patient: the risk to the patient, and the risk to critical groups exposed to the patient. The method for quantifying the risk to the patient is described in terms of estimating the effective dose. The main limitations in these estimates for adult and paediatric patients are uncertainties in the biokinetic data, and the assumption of a uniform distribution of activity in each organ. Effective doses from most nuclear medicine procedures will not exceed twice the annual dose from natural background radiation in the UK. Lack of human placental transfer data is now the main limitation to estimating fetal doses. The characteristics of two methods which can be used to derive the dose to critical groups exposed to nuclear medicine patients are reviewed. It is shown that studies using either method have indicated that the current recommendations in the UK for restricting the exposure of these groups and the recommendation recently proposed for restricting the exposure of pregnant members of staff are not appropriate. Revised recommendations for restricting the behaviour of patients administered iodine-131 should await the results of a current multicentre trial. The method to estimate the dose to a breast-fed infant from a mother administered a radiopharmaceutical is outlined, and the recently revised guidance for interrupting breast feeding is summarised. When a recommendation for controlling risk is to be derived from dosimetry data obtained from a number of individuals, an outstanding issue to be resolved is the value (e.g. 95% upper confidence limit) on which it should be based.


This article has been cited by other articles:


Home page
JNMHome page
P. Zanotti-Fregonara, C. Champion, R. Trebossen, R. Maroy, J.-Y. Devaux, and E. Hindie
Estimation of the {beta}+ Dose to the Embryo Resulting from 18F-FDG Administration During Early Pregnancy
J. Nucl. Med., April 1, 2008; 49(4): 679 - 682.
[Abstract] [Full Text] [PDF]


Home page
Hum ReprodHome page
A. K. Rao, U. Chitkara, and A. A. Milki
Subclavian vein thrombosis following IVF and ovarian hyperstimulation: a case report
Hum. Reprod., December 1, 2005; 20(12): 3307 - 3312.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M Law, K C Cheng, P M Wu, W Y Ho, and L W C Chow
Patient effective dose from sentinel lymph node lymphoscintigraphy in breast cancer: a study using a female humanoid phantom and thermoluminescent dosemeters
Br. J. Radiol., November 1, 2003; 76(911): 818 - 823.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D Pearson, A T Rogers, and E Moss
A generic approach to risk assessment for the Ionising Radiations Regulations 1999
Br. J. Radiol., January 1, 2001; 74(877): 62 - 68.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
M J O'Doherty, P R McElhatton, and S H L Thomas
Treating thyrotoxicosis in pregnant or potentially pregnant women
BMJ, January 2, 1999; 318(7175): 5 - 6.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.