BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Broadhead, D. A.
Right arrow Articles by McCallum, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Broadhead, D. A.
Right arrow Articles by McCallum, H.

The British Journal of Radiology, Vol 70, Issue 833 492-497, Copyright © 1997 by British Institute of Radiology


ARTICLES

The impact of cardiology on the collective effective dose in the North of England

DA Broadhead, CL Chapple, K Faulkner, ML Davies and H McCallum
Regional Medical Physics Department, Newcastle General Hospital, Newcastle Upon Tyne, UK.

Two cardiology X-ray rooms were monitored with dose-area product meters as part of a Regional Patient Dosimetry Programme. Dose-area product measurements on over 2000 patients undergoing examinations in the cardiology rooms are presented. The data have been corrected according to patient size where possible. In room A mean dose-area product values for coronary angiography, coronary angioplasty, radiofrequency ablation and mitral valvuloplasty were found to be 47.7, 72.2, 91.1 and 161.9 Gy cm2 respectively. In room B mean dose-area product values for coronary angiography and coronary angioplasty were found to be 23.4 and 51.6 Gy cm2 respectively. Observational studies were used to deduce the typical projections and technique factors. This typical examination was used to simulate an angiogram from which it was possible to derive factors to convert measured dose-area product values into estimates of effective dose. In room A, the effective doses were estimated to be 9.4, 14.2, 17.3 and 29.3 mSv for coronary angiography, coronary angioplasty, radiofrequency ablation and mitral valvuloplasty, respectively. The effective doses during coronary angiography and coronary angioplasty, performed in room B, were found to be 4.6 and 10.2 mSv, respectively. A regional survey of the frequency of these cardiac procedures was performed. It was deduced that the annual collective effective dose from these cardiac procedures in the North of England, the former Northern Region, was 45.7 manSv.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
Z. Brnic, T. Krpan, D. Faj, D. Kubelka, J. P. Ramac, D. Posedel, R. Steiner, V. Vidjak, V. Brnic, K. Viskovic, et al.
PATIENT RADIATION DOSES IN THE MOST COMMON INTERVENTIONAL CARDIOLOGY PROCEDURES IN CROATIA: FIRST RESULTS
Radiat Prot Dosimetry, October 30, 2009; (2009) ncp237v1.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
C J D'HELFT, P C BRENNAN, A M MCGEE, S L MCFADDEN, C M HUGHES, J R WINDER, and L A RAINFORD
Potential Irish dose reference levels for cardiac interventional examinations
Br. J. Radiol., April 1, 2009; 82(976): 296 - 302.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Tsapaki, S. Kottou, S. Korniotis, N. Nikolaki, S. Rammos, and S. C. Apostolopoulou
RADIATION DOSES IN PAEDIATRIC INTERVENTIONAL CARDIOLOGY PROCEDURES
Radiat Prot Dosimetry, January 2, 2009; (2009) ncn313v1.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K FAULKNER and A WERDUCH
An estimate of the collective dose to the European population from cardiac X-ray procedures
Br. J. Radiol., December 1, 2008; 81(972): 955 - 962.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Bogaert, K. Bacher, and H. Thierens
INTERVENTIONAL CARDIOVASCULAR PROCEDURES IN BELGIUM: EFFECTIVE DOSE AND CONVERSION FACTORS
Radiat Prot Dosimetry, April 2, 2008; (2008) ncn021v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Faulkner and A. Werduch
ANALYSIS OF THE FREQUENCY OF INTERVENTIONAL CARDIOLOGY IN VARIOUS EUROPEAN COUNTRIES
Radiat Prot Dosimetry, March 16, 2008; (2008) ncn020v1.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Earls, E. L. Berman, B. A. Urban, C. A. Curry, J. L. Lane, R. S. Jennings, C. C. McCulloch, J. Hsieh, and J. H. Londt
Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose
Radiology, March 1, 2008; 246(3): 742 - 753.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
O W E Morrish and K E Goldstone
An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures
Br. J. Radiol., January 1, 2008; 81(961): 35 - 45.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. J. Einstein, K. W. Moser, R. C. Thompson, M. D. Cerqueira, and M. J. Henzlova
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Circulation, September 11, 2007; 116(11): 1290 - 1305.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Ector, O. Dragusin, B. Adriaenssens, W. Huybrechts, R. Willems, H. Ector, and H. Heidbuchel
Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial Fibrillation
J. Am. Coll. Cardiol., July 17, 2007; 50(3): 234 - 242.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
K. Vijayalakshmi, D. Kelly, C.-L. Chapple, D. Williams, R. Wright, M. J Stewart, J. A Hall, A. Sutton, A. Davies, J. Haywood, et al.
Cardiac catheterisation: radiation doses and lifetime risk of malignancy
Heart, March 1, 2007; 93(3): 370 - 371.
[Full Text] [PDF]


Home page
EuropaceHome page
E. P. Efstathopoulos, D. G. Katritsis, S. Kottou, N. Kalivas, E. Tzanalaridou, E. Giazitzoglou, S. Korovesis, and K. Faulkner
Patient and staff radiation dosimetry during cardiac electrophysiology studies and catheter ablation procedures: a comprehensive analysis
Europace, June 1, 2006; 8(6): 443 - 448.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
R. Padovani and E. Quai
Patient dosimetry approaches in interventional cardiology and literature dose data review
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 217 - 221.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. W. Schultz and J. Zoetelief
Dose conversion coefficients for interventional procedures
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 225 - 230.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
O. Dragusin, W. Desmet, H. Heidbuchel, R. Padovani, and H. Bosmans
Radiation dose levels during interventional cardiology procedures in a tertiary care hospital
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 231 - 235.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Trianni, G. Chizzola, H. Toh, E. Quai, E. Cragnolini, G. Bernardi, A. Proclemer, and R. Padovani
Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 241 - 246.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E M Paisley, J P Eatough, P J Mountford, G Frain, and J Pickerill
Patient radiation doses during invasive cardiac procedures categorised by clinical code
Br. J. Radiol., December 1, 2004; 77(924): 1022 - 1026.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
V Tsapaki, S Kottou, N Kollaros, P Dafnomili, M Koutelou, E Vano, and V Neofotistou
Comparison of a conventional and a flat-panel digital system in interventional cardiology procedures
Br. J. Radiol., July 1, 2004; 77(919): 562 - 567.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
V Tsapaki, S Kottou, E Vano, K Faulkner, J Giannouleas, R Padovani, E Kyrozi, M Koutelou, E Vardalaki, and V Neofotistou
Patient dose values in a dedicated Greek cardiac centre
Br. J. Radiol., October 1, 2003; 76(910): 726 - 730.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
W R Arthur, J Dhawan, M S Norell, A J Hunter, and A L Clark
Does cardiologist- or radiographer-operated fluoroscopy and image acquisition influence optimization of patient radiation exposure during routine coronary angiography?
Br. J. Radiol., September 1, 2002; 75(897): 748 - 753.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S L McFadden, R B Mooney, and P H Shepherd
X-ray dose and associated risks from radiofrequency catheter ablation procedures
Br. J. Radiol., March 1, 2002; 75(891): 253 - 265.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Vano, J Goicolea, C Galvan, L Gonzalez, L Meiggs, J I Ten, and C Macaya
Skin radiation injuries in patients following repeated coronary angioplasty procedures
Br. J. Radiol., November 1, 2001; 74(887): 1023 - 1031.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
P WILDE, E M PITCHER, and K SLACK
Radiation hazards for the patient in cardiological procedures
Heart, February 1, 2001; 85(2): 127 - 130.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.