BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seymour, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seymour, R.

The British Journal of Radiology, Vol 70, Issue 833 489-491, Copyright © 1997 by British Institute of Radiology


ARTICLES

Patient dose reduction by audit of grid usage in barium enemas

R Seymour
Department of Radiology, University Hospital of Wales Healthcare NHS Trust, Heath Park, Cardiff, UK.

Patient dose reduction may be achieved by removal of the antiscatter grid during fluoroscopy when fine detail is not required, such as during the filling phase of barium enemas. A questionnaire revealed that none of 22 trainee radiologists routinely removed the grid for the filling phase of adult barium enemas. Following this, 100 consecutive barium enemas were observed, with assessment of patient radiation dose by means of a dose-area product meter. The grid was removed in only six examinations. Phantom measurements implied a possible 46% reduction in dose for the filling phase by correct grid usage. These data were presented at a local clinical audit meeting, resulting in a change in departmental policy to recommend routine removal of the grid for the filling phase of barium enemas. In a follow-up audit the grid was removed in 96 of 100 consecutive enemas, resulting in a significant 46.5% dose reduction for the filling phase (95% confidence interval 38-61%). Further re-audit has demonstrated continued good practice.


This article has been cited by other articles:


Home page
radtechHome page
J. NIGHTINGALE and P. HOGG
The Role of the GI Radiographer: A United Kingdom Perspective
Radiol. Technol., March 1, 2007; 78(4): 284 - 290.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. L. Ward, C. E. Barnewolt, K. J. Strauss, R. L. Lebowitz, V. Venkatakrishnan, M. Stehr, D. L. McLellan, C. A. Peters, D. Zurakowski, P. S. Dunning, et al.
Radiation Exposure Reduction during Voiding Cystourethrography in a Pediatric Porcine Model of Vesicoureteral Reflux
Radiology, January 1, 2006; 238(1): 96 - 106.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
R E Morrell, A T Rogers, J C Jobling, and K E Shakespeare
Barium enema: use of increased copper filtration to optimize dose and image quality
Br. J. Radiol., February 1, 2004; 77(914): 116 - 122.