BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Unnik, J. G.
Right arrow Articles by Zweers, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Unnik, J. G.
Right arrow Articles by Zweers, D.

The British Journal of Radiology, Vol 70, Issue 832 367-371, Copyright © 1997 by British Institute of Radiology


ARTICLES

Survey of CT techniques and absorbed dose in various Dutch hospitals

JG Van Unnik, JJ Broerse, J Geleijns, JT Jansen, J Zoetelief and D Zweers
Radiology Department, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands.

The purpose of this study was to make an inventory of the radiation dose from CT in the Netherlands and to relate the dose to the way the examination was performed. Details were obtained from approximately 3000 CT examinations carried out in 18 hospitals (22 CT scanners). Effective dose was calculated for each examination using CTDI-to-effective dose conversion factors. For most scanners, the conversion factors were available from the literature, for some they had to be derived with a computer model using a Monte Carlo algorithm. The data on effective dose, examination parameters and patient population are presented on a per hospital basis. Mean effective doses from brain CT were 0.8-5 mSv, from lumbar spine CT 2-12 mSv, from chest CT 6-18 mSv and from abdominal CT 6-24 mSv. The general indications for the various CT examinations were as follows: for the brain ischaemia and malignancy, for the lumbar spine disc herniation and for the chest and abdomen a known malignancy. This explains the relatively advanced age of the patients. In many hospitals intravenous contrast is used less than is recommended in current literature.


This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. E. Ngaile, P. Msaki, and R. Kazema
Current status of patient radiation doses from computed tomography examinations in Tanzania
Radiat Prot Dosimetry, December 1, 2006; 121(2): 128 - 135.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. A. Taylor, S. Halligan, C. I. Bartram, P. R. Morgan, I. C. Talbot, N. Fry, B. P. Saunders, K. Khosraviani, and W. Atkin
Multi-Detector Row CT Colonography: Effect of Collimation, Pitch, and Orientation on Polyp Detection in a Human Colectomy Specimen
Radiology, October 1, 2003; 229(1): 109 - 118.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
R T M van Soldt, D Zweers, L van den Berg, J Geleijns, J T. M Jansen, and J Zoetelief
Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality
Br. J. Radiol., June 1, 2003; 76(906): 398 - 405.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
V Tsapaki, S Kottou, and D Papadimitriou
Application of European Commission reference dose levels in CT examinations in Crete, Greece
Br. J. Radiol., September 1, 2001; 74(885): 836 - 840.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
W M Teeuwisse, J Geleijns, J J Broerse, W R Obermann, and E L van Persijn van Meerten
Patient and staff dose during CT guided biopsy, drainage and coagulation
Br. J. Radiol., August 1, 2001; 74(884): 720 - 726.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. J. Brenner, C. D. Elliston, E. J. Hall, and W. E. Berdon
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Am. J. Roentgenol., February 1, 2001; 176(2): 289 - 296.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Cohnen, H. Fischer, J. Hamacher, E. Lins, R. Kötter, and U. Mödder
CT of the Head by Use of Reduced Current and Kilovoltage: Relationship between Image Quality and Dose Reduction
AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1654 - 1660.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. Diederich, D. Wormanns, M. Semik, M. Thomas, H. Lenzen, N. Roos, and W. Heindel
Screening for Early Lung Cancer with Low-Dose Spiral CT: Prevalence in 817 Asymptomatic Smokers
Radiology, March 1, 2002; 222(3): 773 - 781.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.