JG Van Unnik, JJ Broerse, J Geleijns, JT Jansen, J Zoetelief and D Zweers
Radiology Department, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands.
The purpose of this study was to make an inventory of the radiation dose from CT in the Netherlands and to relate the dose to the way the examination was performed. Details were obtained from approximately 3000 CT examinations carried out in 18 hospitals (22 CT scanners). Effective dose was calculated for each examination using CTDI-to-effective dose conversion factors. For most scanners, the conversion factors were available from the literature, for some they had to be derived with a computer model using a Monte Carlo algorithm. The data on effective dose, examination parameters and patient population are presented on a per hospital basis. Mean effective doses from brain CT were 0.8-5 mSv, from lumbar spine CT 2-12 mSv, from chest CT 6-18 mSv and from abdominal CT 6-24 mSv. The general indications for the various CT examinations were as follows: for the brain ischaemia and malignancy, for the lumbar spine disc herniation and for the chest and abdomen a known malignancy. This explains the relatively advanced age of the patients. In many hospitals intravenous contrast is used less than is recommended in current literature.
This article has been cited by other articles:
![]() |
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog Radiology, July 1, 2008; 248(1): 254 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Ngaile, P. Msaki, and R. Kazema Current status of patient radiation doses from computed tomography examinations in Tanzania Radiat Prot Dosimetry, December 1, 2006; 121(2): 128 - 135. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Taylor, S. Halligan, C. I. Bartram, P. R. Morgan, I. C. Talbot, N. Fry, B. P. Saunders, K. Khosraviani, and W. Atkin Multi-Detector Row CT Colonography: Effect of Collimation, Pitch, and Orientation on Polyp Detection in a Human Colectomy Specimen Radiology, October 1, 2003; 229(1): 109 - 118. [Abstract] [Full Text] [PDF] |
||||
![]() |
R T M van Soldt, D Zweers, L van den Berg, J Geleijns, J T. M Jansen, and J Zoetelief Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality Br. J. Radiol., June 1, 2003; 76(906): 398 - 405. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Tsapaki, S Kottou, and D Papadimitriou Application of European Commission reference dose levels in CT examinations in Crete, Greece Br. J. Radiol., September 1, 2001; 74(885): 836 - 840. [Abstract] [Full Text] [PDF] |
||||
![]() |
W M Teeuwisse, J Geleijns, J J Broerse, W R Obermann, and E L van Persijn van Meerten Patient and staff dose during CT guided biopsy, drainage and coagulation Br. J. Radiol., August 1, 2001; 74(884): 720 - 726. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Brenner, C. D. Elliston, E. J. Hall, and W. E. Berdon Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT Am. J. Roentgenol., February 1, 2001; 176(2): 289 - 296. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Cohnen, H. Fischer, J. Hamacher, E. Lins, R. Kötter, and U. Mödder CT of the Head by Use of Reduced Current and Kilovoltage: Relationship between Image Quality and Dose Reduction AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1654 - 1660. [Abstract] [Full Text] |
||||
![]() |
S. Diederich, D. Wormanns, M. Semik, M. Thomas, H. Lenzen, N. Roos, and W. Heindel Screening for Early Lung Cancer with Low-Dose Spiral CT: Prevalence in 817 Asymptomatic Smokers Radiology, March 1, 2002; 222(3): 773 - 781. [Abstract] [Full Text] [PDF] |
||||