BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vehmas, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vehmas, T.

The British Journal of Radiology, Vol 70, Issue 831 296-298, Copyright © 1997 by British Institute of Radiology


ARTICLES

Radiation exposure during standard and complex interventional procedures

T Vehmas
Department of Radiology, Helsinki University Central Hospital, Finland.

Radiation doses given during standard and complex interventional procedures were compared. Screening times, dose-area products, and radiologists' forehead and finger doses were recorded during 28 standard percutaneous drainages and 10 complex drainages (eight combined procedures and two failed procedures). The median screening times (8.75 min) and finger doses (84 microGy) during standard drainages were less than those during complex drainages (20.5 min, p = 0.0005 and 163 microGy, p = 0.0003). Dose-area products and forehead doses were also lower, but not significantly. Previously published series on radiation measurements lack data on complex procedures. This may bias the results, since combined and failed interventions, which are common, are associated with higher radiation exposure than are standard procedures.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
E. Stranden, T. Seske, and A. Widmark
INDICATORS FOR THE FINGER DOSES IN INTERVENTIONAL RADIOLOGY
Radiat Prot Dosimetry, May 24, 2007; (2007) ncm203v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Peterzol, E. Quai, R. Padovani, G. Bernardi, C. J. Kotre, and A. Dowling
Reference levels in PTCA as a function of procedure complexity
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 54 - 58.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M Whitby and C J Martin
A study of the distribution of dose across the hands of interventional radiologists and cardiologists
Br. J. Radiol., March 1, 2005; 78(927): 219 - 229.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M Whitby and C J Martin
Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?
Br. J. Radiol., May 1, 2003; 76(905): 321 - 327.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Buls, J Pages, F Mana, and M Osteaux
Patient and staff exposure during endoscopic retrograde cholangiopancreatography
Br. J. Radiol., May 31, 2002; 75(893): 435 - 443.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J M C Gallet and M H Reed
Paediatric personnel extremity dose study
Br. J. Radiol., March 1, 2002; 75(891): 249 - 252.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. N. King, A. M. Champlin, C. A. Kelsey, and D. A. Tripp
Using a Sterile Disposable Protective Surgical Drape for Reduction of Radiation Exposure to Interventionalists
Am. J. Roentgenol., January 1, 2002; 178(1): 153 - 157.
[Abstract] [Full Text] [PDF]


Home page
Occup. Environ. Med.Home page
L. Fritschi
Cancer in veterinarians
Occup. Environ. Med., May 1, 2000; 57(5): 289 - 297.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1997 by the British Institute of Radiology.