BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1996) 69, 601-609
© 1996 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chrysikopoulos, H.
Right arrow Articles by Andreou, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chrysikopoulos, H.
Right arrow Articles by Andreou, J.

The British Journal of Radiology, Vol 69, Issue 823 601-609, Copyright © 1996 by British Institute of Radiology


ARTICLES

Acute subarachnoid haemorrhage: detection with magnetic resonance imaging

H Chrysikopoulos, N Papanikolaou, J Pappas, A Papandreou, A Roussakis, J Vassilouthis and J Andreou
Department of Radiology, Hygeia Hospital, Marousi, Athens, Greece.

The purpose of this study was the evaluation of fluid attenuated turbo inversion recovery (FLAT TIRE) MR pulse sequence for detecting acute subarachnoid hemorrhage (SAH). Seven patients with SAH were studied within 6 days of ictus. Six of them underwent both CT and MRI and one MRI only. Pulse sequences included T1 spin echo (SE), PD and T2 turbo spin echo (TSE) and FLAT TIRE (TR/TI/TE = 6500/1800/140-180). All studies were performed on a 0.5 T system (Gyroscan T5, Philips Medical Systems). Simulated acute SAH was also studied with MRI. The FLAT TIRE sequence was better than the SE and TSE in all seven cases and better than CT in two cases. In two cases MRI was equivalent to CT, and in another two MRI underestimated the extent of SAH. The simulated acute SAH could be detected easily with the FLAT TIRE sequence, with difficulty on the T1 weighted images and not at all on the PD/T2 weighted images. The specific FLAT TIRE sequence used seems promising for the detection of acute SAH.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
A. Cianfoni, M.G.M. Martin, J. Du, J.R. Hesselink, S.G. Imbesi, W.G. Bradley, and G.M. Bydder
Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 843 - 849.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. D. Griffiths, I. D. Wilkinson, P. Mitchell, M. C. Patel, M. N.J. Paley, C. A.J. Romanowski, T. Powell, T. J. Hodgson, N. Hoggard, and D. Jellinek
Multimodality MR Imaging Depiction of Hemodynamic Changes and Cerebral Ischemia in Subarachnoid Hemorrhage
AJNR Am. J. Neuroradiol., October 1, 2001; 22(9): 1690 - 1697.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R. J. Woodcock Jr, J. Short, H. M. Do, M. E. Jensen, and D. F. Kallmes
Imaging of Acute Subarachnoid Hemorrhage with a Fluid-Attenuated Inversion Recovery Sequence in an Animal Model: Comparison with Non-Contrast-Enhanced CT
AJNR Am. J. Neuroradiol., October 1, 2001; 22(9): 1698 - 1703.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
D. D. M. Lin, C. G. Filippi, A. B. Steever, and R. D. Zimmerman
Detection of Intracranial Hemorrhage: Comparison between Gradient-echo Images and b0 Images Obtained from Diffusion-weighted Echo-planar Sequences
AJNR Am. J. Neuroradiol., August 1, 2001; 22(7): 1275 - 1281.
[Abstract] [Full Text] [PDF]


Home page
J. Neurol. Neurosurg. PsychiatryHome page
P Mitchell, I D Wilkinson, N Hoggard, M N J Paley, D A Jellinek, T Powell, C Romanowski, T Hodgson, and P D Griffiths
Detection of subarachnoid haemorrhage with magnetic resonance imaging
J. Neurol. Neurosurg. Psychiatry, February 1, 2001; 70(2): 205 - 211.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. Noguchi, H. Seto, Y. Kamisaki, G. Tomizawa, S. Toyoshima, and N. Watanabe
Comparison of Fluid-attenuated Inversion-recovery MR Imaging with CT in a Simulated Model of Acute Subarachnoid Hemorrhage
AJNR Am. J. Neuroradiol., May 1, 2000; 21(5): 923 - 927.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1996 by the British Institute of Radiology.