| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
The British Journal of Radiology, Vol 69, Issue 821 426-431, Copyright © 1996 by British Institute of Radiology
ARTICLES |
KC Leung and CJ Martin
Department of Bio-Medical Physics and Bio-Engineering, Aberdeen University, Foresterhill, UK.
A detailed study of dose data has been made for 100 coronary angiography examinations performed on a digital X-ray unit. Dose-area product (DAP) data have been analysed in terms of fluoroscopy and radiography for different projections. Projections patterns were similar for all cardiologists studied and the contribution to DAP from fluoroscopy was 32%. Data for 10 patients, selected because the percentage contributions to DAP from fluoroscopy and radiography were similar to the mean for the group, were used to derive conversion factors from DAP to effective dose. The mean DAP was 14 Gy cm2 and the effective dose 3.1 mSv. Conversion factors, based on the same protocol, were derived for a range of tube potentials and filtrations for use in estimation of effective doses with other units.
This article has been cited by other articles:
![]() |
K FAULKNER and A WERDUCH An estimate of the collective dose to the European population from cardiac X-ray procedures Br. J. Radiol., December 1, 2008; 81(972): 955 - 962. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog Radiology, July 1, 2008; 248(1): 254 - 263. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Martin RADIATION DOSIMETRY FOR DIAGNOSTIC MEDICAL EXPOSURES Radiat Prot Dosimetry, March 28, 2008; (2008) ncm495v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Earls, E. L. Berman, B. A. Urban, C. A. Curry, J. L. Lane, R. S. Jennings, C. C. McCulloch, J. Hsieh, and J. H. Londt Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose Radiology, March 1, 2008; 246(3): 742 - 753. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Einstein, K. W. Moser, R. C. Thompson, M. D. Cerqueira, and M. J. Henzlova Radiation Dose to Patients From Cardiac Diagnostic Imaging Circulation, September 11, 2007; 116(11): 1290 - 1305. [Full Text] [PDF] |
||||
![]() |
A. Deetjen, S. Mollmann, G. Conradi, A. Rolf, A. Schmermund, C. W Hamm, and T. Dill Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography Heart, September 1, 2007; 93(9): 1040 - 1043. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Vijayalakshmi, D. Kelly, C.-L. Chapple, D. Williams, R. Wright, M. J Stewart, J. A Hall, A. Sutton, A. Davies, J. Haywood, et al. Cardiac catheterisation: radiation doses and lifetime risk of malignancy Heart, March 1, 2007; 93(3): 370 - 371. [Full Text] [PDF] |
||||
![]() |
D G W Onnasch, F K Schroder, G Fischer, and H-H Kramer Diagnostic reference levels and effective dose in paediatric cardiac catheterization Br. J. Radiol., March 1, 2007; 80(951): 177 - 185. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. R. C. Johnson, K. Nikolaou, B. J. Wintersperger, A. Knez, P. Boekstegers, M. F. Reiser, and C. R. Becker ECG-Gated 64-MDCT Angiography in the Differential Diagnosis of Acute Chest Pain Am. J. Roentgenol., January 1, 2007; 188(1): 76 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Peterzol, E. Quai, R. Padovani, G. Bernardi, C. J. Kotre, and A. Dowling Reference levels in PTCA as a function of procedure complexity Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 54 - 58. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Padovani and E. Quai Patient dosimetry approaches in interventional cardiology and literature dose data review Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 217 - 221. [Abstract] [Full Text] [PDF] |
||||
![]() |
E M Paisley, J P Eatough, P J Mountford, G Frain, and J Pickerill Patient radiation doses during invasive cardiac procedures categorised by clinical code Br. J. Radiol., December 1, 2004; 77(924): 1022 - 1026. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Kuon, C Glaser, and J B Dahm Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures Br. J. Radiol., June 1, 2003; 76(906): 406 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Kuon, J B Dahm, M Schmitt, C Glaser, O Gefeller, and A Pfahlberg Time of day influences patient radiation exposure from percutaneous cardiac interventions Br. J. Radiol., March 1, 2003; 76(903): 189 - 191. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Hunold, F. M. Vogt, A. Schmermund, J. F. Debatin, G. Kerkhoff, T. Budde, R. Erbel, K. Ewen, and J. Barkhausen Radiation Exposure during Cardiac CT: Effective Doses at Multi-Detector Row CT and Electron-Beam CT Radiology, January 1, 2003; 226(1): 145 - 152. [Abstract] [Full Text] [PDF] |
||||
![]() |
W R Arthur, J Dhawan, M S Norell, A J Hunter, and A L Clark Does cardiologist- or radiographer-operated fluoroscopy and image acquisition influence optimization of patient radiation exposure during routine coronary angiography? Br. J. Radiol., September 1, 2002; 75(897): 748 - 753. [Abstract] [Full Text] [PDF] |
||||
![]() |
P WILDE, E M PITCHER, and K SLACK Radiation hazards for the patient in cardiological procedures Heart, February 1, 2001; 85(2): 127 - 130. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| BJR | DMFR | IMAGING | ALL BIR JOURNALS |