British Journal of Radiology (1996) 69, 422-425
© 1996 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huda, W.
Right arrow Articles by Morin, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huda, W.
Right arrow Articles by Morin, R. L.

The British Journal of Radiology, Vol 69, Issue 821 422-425, Copyright © 1996 by British Institute of Radiology


ARTICLES

Patient doses in bone mineral densitometry

W Huda and RL Morin
University of Florida, Department of Radiology, JHMHC, Gainesville 32610-0374, USA.

Procedures were developed to compute effective dose equivalent (H(E)) values for patients undergoing bone mineral densitometry (BMD) measurements such as dual energy X-ray absorptiometry (DEXA) and quantitative computed tomography (QCT). Representative values of H(E) were determined for patients undergoing each type of BMD procedure. Typical DEXA measurements are associated with an H(E) of about 2.5 microSv. For QCT, the values of H(E) are 300 microSv for single energy techniques and 1 mSv for dual energy techniques, respectively. By comparison, a single well collimated abdominal X-ray examination often taken in conjunction with DEXA studies results in an H(E) of about 100 microSv. BMD patient doses are at the lower end of the exposure range encountered in diagnostic radiology. As a result, radiation dose is not a primary factor in choosing the method for BMD determination.


This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
U. O'Connor, A. Dowling, A Larkin, N. Sheahan, L. Gray, A. Gallagher, G. O'Reilly, A. Kosunen, U. Zdesar, and J. F. Malone
DEVELOPMENT OF TRAINING SYLLABI FOR RADIATION PROTECTION AND QUALITY ASSURANCE OF DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) SYSTEMS
Radiat Prot Dosimetry, April 8, 2008; (2008) ncn088v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Larkin, N. Sheahan, U. O'Connor, L. Gray, A. Dowling, E. Vano, P. Torbica, D. Salat, A. Schreiner, V. Neofotistou, et al.
QA/ACCEPTANCE TESTING OF DEXA X-RAY SYSTEMS USED IN BONE MINERAL DENSITOMETRY
Radiat Prot Dosimetry, April 1, 2008; (2008) ncn086v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
N. F. Sheahan, A. Dowling, G. O'Reilly, and J. F. Malone
Commissioning and quality assurance protocol for dual energy X-ray absorptiometry (DEXA) systems
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 288 - 290.
[Abstract] [Full Text] [PDF]