BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1996) 69, 215-220
© 1996 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hittmair, K.
Right arrow Articles by Schurawitzki, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hittmair, K.
Right arrow Articles by Schurawitzki, H.

The British Journal of Radiology, Vol 69, Issue 819 215-220, Copyright © 1996 by British Institute of Radiology


ARTICLES

Field strength dependence of MRI contrast enhancement: phantom measurements and application to dynamic breast imaging

K Hittmair, K Turetschek, G Gomiscek, R Stiglbauer and H Schurawitzki
MR Institute, University of Vienna, Austria.

Differences in MRI-measured contrast enhancement have been used for tissue characterization, particularly for the characterization of mammary tumours. T1 weighted spoiled gradient echo sequences have usually been acquired for this purpose and relative signal intensity increase (Srel) has been determined to quantify contrast uptake. The field strength dependence of this technique is evaluated in this paper by phantom measurements. Srel is compared with the recently introduced "enhancement factor" (EF) and "contrast uptake equivalent" (CE) as a quantitative assessment parameter for contrast uptake. Enhancing tissues were simulated with water phantoms doped with increasing concentrations of Gd-DTPA. Spoiled gradients echo images (FLASH-2D) were obtained on a 0.2 T and 1.5 T MR system. Srel, EF and CE were determined and the results of the phantom measurements were applied to typical types of breast tissues. Srel showed a strong dependence on the magnetic field strength and was greater at higher field strengths. This is because Srel correlates positively with the native T1 which is longer at higher field strengths. Conversely, the EF and CE almost eliminated the distorting influences of the magnetic field strength. CE provided a good approximation of the actual contrast uptake. In practice, the dependence of Srel on the magnetic field strength might cause malignant lesions to be misclassified as benign at low field strengths. Either Srel criteria should be adjusted to magnetic field strength or EF and CE should be used instead of Srel for tissue characterization with dynamic contrast-enhanced MRI.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1996 by the British Institute of Radiology.