BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1995) 68, 1316-1324
© 1995 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Held, P.
Right arrow Articles by Gmeinwieser, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Held, P.
Right arrow Articles by Gmeinwieser, J.

The British Journal of Radiology, Vol 68, Issue 816 1316-1324, Copyright © 1995 by British Institute of Radiology


ARTICLES

Three-dimensional MP-RAGE--an alternative to conventional three-dimensional FLASH sequences for the diagnosis of viscerocranial tumours?

P Held, C Fellner, F Fellner, A Geissler and J Gmeinwieser
Klinikum der Universitat Regensburg, Institut fur Rontgendiagnostik, Germany.

Imaging with three-dimensional (3D) sequences is a frequently used magnetic resonance (MR) technique in the assessment of ear, nose and throat (ENT) tumours near the skull base. Few reports on the contrast behaviour of 3D magnetization prepared rapid gradient echo (MP-RAGE) sequences and their application in ENT tumours exist in the published literature. This paper discusses whether 3D MP-RAGE is an alternative to conventional 3D gradient echo (3D GE) sequences for the diagnostic evaluation of the visceral cranum. Measurements were performed with a Magnetom SP 63 MR system (Siemens) at 1.5 T. 10 healthy volunteers were examined using 3D FLASH sequences with varied flip angles (90 degrees, 70 degrees, 40 degrees, 20 degrees, 10 degrees) and using 3D MP-RAGE to optimize the signal-to-noise ratio (SNR) of muscle, fat and gland tissue. After this optimization 25 patients with ENT tumours near the skull base were examined with 3D FLASH 40 degrees, 3D MP-RAGE 10 degrees (both before and after application of contrast medium) and with 3D FISP 70 degrees (without contrast medium). SNR and contrast-to-noise ratio (CNR) of tumour, inflammatory disease, brain (white and grey matter), compact bone, fat and muscle were calculated. The advantages of 3D MP-RAGE over 3D FLASH 40 degrees include decreased imaging time with decreased motion artifacts and a relatively high contrast between tumour and surrounding tissues. The tissue contrast yielded by the T1/T2* weighted 3D gradient echo sequence FISP with a flip angle of 70 degrees was not as good as that yielded by 3D MP-RAGE with and without contrast together. In conclusion a combination of contrast enhanced and unenhanced 3D MP-RAGE sequences is the technique of choice for the examination of ENT tumours near the base of the skull.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1995 by the British Institute of Radiology.