British Journal of Radiology (1995) 68, 1221-1229
© 1995 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Warren-Forward, H. M.
Right arrow Articles by Millar, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Warren-Forward, H. M.
Right arrow Articles by Millar, J. S.

The British Journal of Radiology, Vol 68, Issue 815 1221-1229, Copyright © 1995 by British Institute of Radiology


ARTICLES

Optimization of radiographic technique for chest radiography

HM Warren-Forward and JS Millar
RRPPS, Birmingham Medical Physics Service, West Midlands, UK.

Over 1500 patients undergoing chest radiography in the West Midlands have been monitored for entrance surface doses using lithium borate thermoluminescent dosemeters. In total 63 X-ray tubes were monitored from 30 hospital departments. The mean patient entrance surface dose is 0.15 mGy, and the 75th percentile entrance surface dose is 0.18 mGy. A reference level of 0.18 mGy has been recommended for PA chest radiography in the West Midlands. Image quality has been assessed on patient radiographs. Departmental radiologists were responsible for assessing radiographs taken within their hospital. Independent analysis was performed by a control radiologist. Film-screen processor sensitivity has been assessed on 48 film-screen processor combinations. Significant differences were observed between the nominally quoted sensitivities and the measured sensitivities. Only 26% of systems produced measured sensitivities within 10% of the nominal values. A four variable regression model, explaining 78% of the variance, provided the best description for the variation in patient dose. These variables were actual sensitivity, applied potential, generator waveform and radiographic quality. Four recommendations have been made to lower patient doses; these are: (1) an increase in applied potential to a minimum of 90 kVp; (2) a film-screen sensitivity of 400; (3) optimization of processor performance and (4) regular radiological audits to reduce repeat rates to a level of 5%. If all of these recommendations are followed, an estimated overall entrance surface dose saving of 53% would result. Changing the applied potential alone will see the variation in the mean entrance surface dose from non-gridded systems reduce from a factor of 4 to a factor of 2.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
M. Ward, D. Hughes, P. Connolly, and B. M. Moores
Central dose data management and analysis in IT-driven radiation protection strategies
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 135 - 142.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J Vassileva
A phantom approach to find the optimal technical parameters for plain chest radiography
Br. J. Radiol., August 1, 2004; 77(920): 648 - 653.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K K L Fung and W B Gilboy
The effect of beam tube potential variation on gonad dose to patients during chest radiography investigated using high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeters
Br. J. Radiol., April 1, 2001; 74(880): 358 - 367.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1995 by the British Institute of Radiology.