BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1995) 68, 1215-1220
© 1995 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vano, E.
Right arrow Articles by Guibelalde, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vano, E.
Right arrow Articles by Guibelalde, E.

The British Journal of Radiology, Vol 68, Issue 815 1215-1220, Copyright © 1995 by British Institute of Radiology


ARTICLES

Patient dose values in interventional radiology

E Vano, L Gonzalez, JM Fernandez and E Guibelalde
Radiology Department, School of Medicine, Complutense University, Madrid, Spain.

Large exposures incurred in interventional radiology procedures make it advisable to establish reference dose values. These dose values should be quoted in quantities representative of the radiological risk to the patient. In Spain, measurement methods were developed to comply with the European Directive on Patient Protection. Dose-area product and, when feasible, surface dose using thermoluminescent dosimetry chips were measured. Both approaches are discussed, as well as their potential use in patient protection programmes. Initial results are presented for a sample of 680 patients in 10 hospital centres in Spain. Mean, median and range are reported for some specific procedures. Mean values of 8750, 6651, 6663, 9292 and 6816 cGy cm2 are reported for percutaneous transluminal coronary angioplasty, coronary angiography, low extremity, renal and cerebral arteriographies, respectively.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
K FAULKNER and A WERDUCH
An estimate of the collective dose to the European population from cardiac X-ray procedures
Br. J. Radiol., December 1, 2008; 81(972): 955 - 962.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T. Moritake, Y. Matsumaru, T. Takigawa, K. Nishizawa, A. Matsumura, and K. Tsuboi
Dose Measurement on Both Patients and Operators during Neurointerventional Procedures Using Photoluminescence Glass Dosimeters
AJNR Am. J. Neuroradiol., November 1, 2008; 29(10): 1910 - 1917.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Smans, L. Struelens, M. Smet, H. Bosmans, and F. Vanhavere
PATIENT DOSE IN NEONATAL UNITS
Radiat Prot Dosimetry, August 30, 2008; (2008) ncn237v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Smans, L. Struelens, M.-T. Hoornaert, F. Bleeser, N. Buls, D. Berus, P. Clerinx, F. Malchair, F. Vanhavere, and H. Bosmans
A study of the correlation between dose area product and effective dose in vascular radiology
Radiat Prot Dosimetry, July 1, 2008; 130(3): 300 - 308.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
C. D'Helft, A. McGee, L. Rainford, S. Mc Fadden, J. Winder, C. Hughes, and P. C. Brennan
PROPOSED PRELIMINARY DIAGNOSTIC REFERENCE LEVELS FOR THREE COMMON INTERVENTIONAL CARDIOLOGY PROCEDURES IN IRELAND
Radiat Prot Dosimetry, April 16, 2008; (2008) ncn048v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
C. J. Martin
RADIATION DOSIMETRY FOR DIAGNOSTIC MEDICAL EXPOSURES
Radiat Prot Dosimetry, March 28, 2008; (2008) ncm495v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Faulkner and A. Werduch
ANALYSIS OF THE FREQUENCY OF INTERVENTIONAL CARDIOLOGY IN VARIOUS EUROPEAN COUNTRIES
Radiat Prot Dosimetry, March 16, 2008; (2008) ncn020v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Tsapaki, C. Triantopoulou, P. Maniatis, S. Kottou, J. Tsalafoutas, and J. Papailiou
PATIENT SKIN DOSE ASSESSMENT DURING CT-GUIDED INTERVENTIONAL PROCEDURES
Radiat Prot Dosimetry, March 8, 2008; (2008) ncn007v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. Bleeser, M.-T. Hoornaert, K. Smans, L. Struelens, N. Buls, D. Berus, P. Clerinx, L. Hambach, F. Malchair, and H. Bosmans
Diagnostic reference levels in angiography and interventional radiology: a Belgian multi-centre study
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 50 - 55.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Vano, H. Jarvinen, A. Kosunen, R. Bly, J. Malone, A. Dowling, A. Larkin, R. Padovani, H. Bosmans, O. Dragusin, et al.
Patient dose in interventional radiology: a European survey
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 39 - 45.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Bogaert, K. Bacher, and H. Thierens
A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment
Radiat Prot Dosimetry, February 1, 2008; 128(3): 312 - 323.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
O W E Morrish and K E Goldstone
An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures
Br. J. Radiol., January 1, 2008; 81(961): 35 - 45.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Papageorgiou, V. Tsapaki, I. A. Tsalafoutas, E. Maurikou, S. Kottou, A. Orfanos, G. Karidas, T. Fidanis, E. Zafiriadou, and V. Neofotistou
Comparison of patient doses in interventional radiology procedures performed in two large hospitals in Greece
Radiat Prot Dosimetry, August 17, 2007; (2007) ncm136v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Tsapaki, S. Kottou, E. Vano, T. Parviainen, R. Padovani, A. Dowling, M. Molfetas, and V. Neofotistou
Correlation of patient and staff doses in interventional cardiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 26 - 29.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Faulkner
Personnel and patient doses: are there ethical consequences to the use of X-rays?
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 30 - 33.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
D. Bor, S. Cekirge, T. Turkay, O. Turan, M. Gulay, E. Onal, and B. Cil
Patient and staff doses in interventional neuroradiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 62 - 68.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
L. Struelens, F. Vanhavere, H. Bosmans, R. Van Loon, and M. Geukens
Data analysis from a multi-centre, comparative study of angiographic examinations leading to practical guidelines for the optimisation of patient doses
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 87 - 92.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
D. Papadopoulou, Em. Yakoumakis, P. Sandilos, V. Thanopoulos, Tr. Makri, G. Gialousis, D. Houndas, N. Yakoumakis, and Ev. Georgiou
Entrance radiation doses during paediatric cardiac catheterisations performed for diagnosis or the treatment of congenital heart disease
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 236 - 240.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
R. Padovani and E. Quai
Patient dosimetry approaches in interventional cardiology and literature dose data review
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 217 - 221.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
O. Dragusin, W. Desmet, H. Heidbuchel, R. Padovani, and H. Bosmans
Radiation dose levels during interventional cardiology procedures in a tertiary care hospital
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 231 - 235.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Trianni, G. Chizzola, H. Toh, E. Quai, E. Cragnolini, G. Bernardi, A. Proclemer, and R. Padovani
Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 241 - 246.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A Karambatsakidou, P Tornvall, N Saleh, T Chouliaras, P-O Lofberg, and A Fransson
Skin dose alarm levels in cardiac angiography procedures: is a single DAP value sufficient?
Br. J. Radiol., September 1, 2005; 78(933): 803 - 809.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
L. Struelens, F. Vanhavere, H. Bosmans, R. Van Loon, and H. Mol
Skin dose measurements on patients for diagnostic and interventional neuroradiology: a multicentre study
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 143 - 146.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E M Paisley, J P Eatough, P J Mountford, G Frain, and J Pickerill
Patient radiation doses during invasive cardiac procedures categorised by clinical code
Br. J. Radiol., December 1, 2004; 77(924): 1022 - 1026.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. G. Delichas, K. Hatziioannou, E. Papanastassiou, P. Albanopoulou, E. Chatzi, A. Sioundas, and K. Psarrakos
Radiation doses to patients undergoing barium meal and barium enema examinations
Radiat Prot Dosimetry, July 1, 2004; 109(3): 243 - 247.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D Bor, T Sancak, T Olgar, Y Elcim, A Adanali, U Sanlidilek, and S Akyar
Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology
Br. J. Radiol., April 1, 2004; 77(916): 315 - 322.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
V Tsapaki, S Kottou, E Vano, K Faulkner, J Giannouleas, R Padovani, E Kyrozi, M Koutelou, E Vardalaki, and V Neofotistou
Patient dose values in a dedicated Greek cardiac centre
Br. J. Radiol., October 1, 2003; 76(910): 726 - 730.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
G J Kemerink, M W de Haan, G B C Vasbinder, M J Frantzen, F W Schultz, J Zoetelief, J T. M Jansen, and J M A van Engelshoven
The effect of equipment set up on patient radiation dose in conventional and CT angiography of the renal arteries
Br. J. Radiol., September 1, 2003; 76(909): 625 - 630.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
C Theodorakou and J A Horrocks
A study on radiation doses and irradiated areas in cerebral embolisation
Br. J. Radiol., August 1, 2003; 76(908): 546 - 552.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
W R Arthur, J Dhawan, M S Norell, A J Hunter, and A L Clark
Does cardiologist- or radiographer-operated fluoroscopy and image acquisition influence optimization of patient radiation exposure during routine coronary angiography?
Br. J. Radiol., September 1, 2002; 75(897): 748 - 753.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Vano, J Goicolea, C Galvan, L Gonzalez, L Meiggs, J I Ten, and C Macaya
Skin radiation injuries in patients following repeated coronary angioplasty procedures
Br. J. Radiol., November 1, 2001; 74(887): 1023 - 1031.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Vano, L Gonzalez, J I Ten, J M Fernandez, E Guibelalde, and C Macaya
Skin dose and dose-area product values for interventional cardiology procedures
Br. J. Radiol., January 1, 2001; 74(877): 48 - 55.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1995 by the British Institute of Radiology.