BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1995) 68, 1087-1089
© 1995 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ablett, M. J.
Right arrow Articles by Butler, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ablett, M. J.
Right arrow Articles by Butler, T. J.

The British Journal of Radiology, Vol 68, Issue 814 1087-1089, Copyright © 1995 by British Institute of Radiology


ARTICLES

How reliable are ultrasound measurements of renal length in adults?

MJ Ablett, A Coulthard, RE Lee, DL Richardson, T Bellas, JP Owen, MJ Keir and TJ Butler
Department of Radiology, Royal Victoria Infirmary, Newcastle upon Tyne, UK.

Ultrasound assessment of patients with renal impairment commonly includes measurement of bipolar renal length. Reduction in length is considered to indicate chronic renal disease and is a factor in deciding whether to proceed to renal biopsy. To date, no published data are available on interobserver and intraobserver variation in sonographic renal length measurement in adults. Bilateral renal lengths were measured in 20 adult subjects, with no history of renal disease, by three experienced operators, on two separate occasions. Limits of agreement for replicate measurements by each ultrasonographer and for replicate measurements by each pair of ultrasonographers were determined. Values of repeatability (a measure of intraobserver variation) and reproducibility (a measure of interobserver variation) were calculated for all renal length measurements, and for right and left renal lengths separately. Results indicate that replicate renal length measurements differ by less than 1.85 cm in 95% of cases, and the magnitude of variations is similar when measurements are made by either single or different ultrasonographers, and are similar for right and left renal length measurements. This suggests that sonographic bipolar renal length measurements in normal adult kidneys are reasonably reliable. In diseased kidneys, however, in which identification of renal poles is difficult, interobserver and intraobserver variation may be much greater.


This article has been cited by other articles:


Home page
ImagingHome page
C C Geddes and G M Baxter
Renal impairment
Imaging, March 1, 2008; 20(1): 1 - 19.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
C C Geddes and G M Baxter
Renal impairment
Imaging, January 1, 2005; 17(1): 1 - 18.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E Widjaja, J W Oxtoby, T L Hale, P W Jones, P N Harden, and I W McCall
Ultrasound measured renal length versus low dose CT volume in predicting single kidney glomerular filtration rate
Br. J. Radiol., September 1, 2004; 77(921): 759 - 764.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Bakker, M. Olree, R. Kaatee, E. E. de Lange, K. G. M. Moons, J. J. Beutler, and F. J. A. Beek
Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR Imaging
Radiology, June 1, 1999; 211(3): 623 - 628.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1995 by the British Institute of Radiology.