BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1995) 68, 1052-1057
© 1995 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rebollo, A. C.
Right arrow Articles by Mateo, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rebollo, A. C.
Right arrow Articles by Mateo, A.

The British Journal of Radiology, Vol 68, Issue 814 1052-1057, Copyright © 1995 by British Institute of Radiology


ARTICLES

Evaluation of palpable breast masses with 201Tl scintigraphy

AC Rebollo, M Torres-Avisbal, JE Espinosa, C Diaz, JA Vallejo, C Pacheco, C Pera and A Mateo
Nuclear Medicine Service, Hospital Reina Sofia, Cordoba, Spain.

39 female patients (age range: 31-84 years) with palpable breast masses detected by physical examination, underwent 201Tl scintigraphy in order to assess its value in the detection of breast carcinomas and to differentiate them from benign breast masses. Planar images were carried out at 20-30 min and 2-3 h after intravenous administration of 111-185 MBq (3-5 mCi) of 201Tl chloride. In 12 patients single photon emission tomography (SPET) studies were also performed. In 18 patients the scintigraphic studies were positive and in 17 of these cases, breast carcinomas were confirmed. Tumour sizes ranged from 1.3 to 6 cm in diameter. In the remaining patient a false positive result was obtained where there was benign breast change. In three of seven cases, malignant axillary nodes were also detected. All 21 patients with negative scintigraphy had benign breast lesions. There were no differences between images obtained at 20-30 min and 2-3 h or between planar images and SPET studies. In 10 patients there was disagreement between mammography and 201Tl scans. 201Tl scans confirmed the presence of carcinoma in three cases and discarded malignancy in the other six cases. In the remaining case, 201Tl scan was false positive. 201Tl scintigraphy is useful in distinguishing malignant from benign breast masses, even when compared with mammography.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1995 by the British Institute of Radiology.