BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1995) 68, 877-881
© 1995 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Faulkner, K.
Right arrow Articles by Robson, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Faulkner, K.
Right arrow Articles by Robson, K. J.

The British Journal of Radiology, Vol 68, Issue 812 877-881, Copyright © 1995 by British Institute of Radiology


ARTICLES

Assessment of mean glandular dose in mammography

K Faulkner, J Law and KJ Robson
Regional Medical Physics Department, Newcastle General Hospital, Newcastle upon Tyne, UK.

The routine assessment of patient dose in the National Health Service Breast Screening Programme is performed as part of the quality assurance protocol recommended by the Institute of Physical Sciences in Medicine. The mean glandular dose to a standard breast is deduced from measurement of the air kerma at the entrance surface of a 4 cm Perspex phantom by applying a series of conversion factors. The exposure factors for this measurement are those used clinically. The measured mean glandular dose is then compared with nationally accepted action levels. In some centres the assessment of mean glandular dose using Perspex is supplemented by patient dose surveys. The mean glandular dose to a series of patients attending a breast screening unit may be estimated from a knowledge of the exposure factors and compressed breast thickness, using a knowledge of the X-ray tube output. Measurements made on units in the Northern Region of England and in Scotland using both methods are presented. The implication of these measurements with regard to patient dose surveys in mammography and quality assurance programmes are discussed. An analysis of the uncertainties associated with the measurement techniques is presented.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
M ROBINSON and C J KOTRE
Trends in compressed breast thickness and radiation dose in breast screening mammography
Br. J. Radiol., March 1, 2008; 81(963): 214 - 218.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J Law
Breast dose from magnification films in mammography
Br. J. Radiol., September 1, 2005; 78(933): 816 - 820.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Jamal, K-H Ng, and D McLean
A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it
Br. J. Radiol., April 1, 2003; 76(904): 238 - 245.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Boone
Glandular Breast Dose for Monoenergetic and High-Energy X-ray Beams: Monte Carlo Assessment
Radiology, October 1, 1999; 213(1): 23 - 37.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1995 by the British Institute of Radiology.