BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1994) 67, 872-876
© 1994 British Institute of Radiology
doi: 10.1259/0007-1285-67-801-872

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crawley, M T
Right arrow Articles by Rogers, A T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Crawley, M T
Right arrow Articles by Rogers, A T

A comparison of computed tomography practice in 1989 and 1991

M T Crawley, MSc, MIPSM 1 and A T Rogers, MSc MIPSM 2

1 Medical Physics Department, Stoke Mandeville Hospital, Mandeville Road, Aylesbury, Bucks HP21 8AL 2 Medical Physics Department, Nottingham City Hospital NHS Trust, Hucknall Road, Nottingham NG5 1PB

In December 1991, the National Radiological Protection Board (NRPB) published the results of national surveys of the frequency, quality assurance and dosimetric aspects of computed tomography (CT) examinations carried out in hospitals in the UK in 1989. A study of the patient records at two of the original participating hospitals was undertaken to establish whether there had been any change in CT practice between the years 1989 and 1991. Aspects of examination frequency, age distribution and dose were analysed. The results showed significant variations in the patient age distributions between the sub-population studied and the larger sample used by the NRPB, and between the patient age distribution for CT examinations in the years 1989 and 1991 at the two hospitals in this study. The results also showed that in one hospital, where magnetic resonance imaging (MRI) was available and where dose reduction measures had been implemented, there was a net decrease in the collective effective dose from 1989 to 1991, whilst at the other hospital, where MRI was not available and where the introduction of dose saving strategies had been delayed, there was a substantial increase in the collective effective dose from 1989 to 1991. The possibility of continuing increases in the annual collective effective dose attributable to CT underlines the importance of local CT audit to ensure that CT doses are as low as reasonably achievable.

Received for publication December 7, 1993. Revision received February 17, 1994. Accepted for publication March 7, 1994.




This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M T Crawley, A Booth, and A Wainwright
A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved
Br. J. Radiol., July 1, 2001; 74(883): 607 - 614.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1994 by the British Institute of Radiology.