British Journal of Radiology (1994) 67, 556-563
© 1994 British Institute of Radiology
doi: 10.1259/0007-1285-67-798-556

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Morán, P
Right arrow Articles by Vañó, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morán, P
Right arrow Articles by Vañó, E

Comparative study of dose values and image quality in mammography in the area of Madrid

P Morán, PhD M Chevalier, PhD and E Vañó, PhD

Medical Physics Group, Medical School, Complutense University of Madrid, 28040 Madrid, Spain

Dose values and image quality in mammography resulting from a study carried out in the area of Madrid during 1990–1991 are presented in a two-part sequence. In this paper are reported the values of air kerma and mean glandular dose per film estimated at 14 centres by means of the Leeds TOR(MAX) mammographic phantom and from patient samples. The results obtained from patient measurements allow us to deduce that the TOR(MAX) phantom assembly used (4.5 cm thick) is equivalent to an average 5 cm thick compressed breast from the population in the area of Madrid. Approximately 75% of the air kerma values resulting from phantom estimations are below 6.6 and 12.2 mGy for X-ray units with and without grid, respectively. The mean glandular doses per film for 75% of the units with and without grid are below 1.5 and 1.7 mGy, respectively. The results showed that the higher values of both air kerma and mean glandular dose obtained for the units without grid result from the use of slow speed recording systems. On the other hand, the quality control programme carried out shows important faults in the performance of the X-ray units which have an important impact on both dose and image quality. Finally, the third quartile values of the air kerma and mean glandular dose per film (10.4 and 1.7 mGy, respectively), deduced by considering all the units (with and without grid), are proposed to be the reference values of the mammographic examinations during the aforementioned period. In a second paper, the image quality is analysed by using the same Leeds TOR(MAX) phantom. Results for each test object included in the phantom are discussed as a function of the X-ray unit characteristics. Subsequently, the phantom images obtained with each X-ray system are scored and the resulting values are compared with the corresponding dose values, so that the dose–image quality relationship for each unit is obtained.

Received for publication March 23, 1993. Accepted for publication September 30, 1993.




This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Jamal, K-H Ng, and D McLean
A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it
Br. J. Radiol., April 1, 2003; 76(904): 238 - 245.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1994 by the British Institute of Radiology.