Measuring radiation exposure during percutaneous drainages: can shoulder dosemeters be used to estimate finger doses?

Tapio Vehmas, MD and Heikki Tikkanen, MD *

Department of Radiology, University of Helsinki, Haartmaninkatu 4, SF-00290 Helsinki, Finland * Department of Clinical Physiology, Helsinki University Central Hospital, Haartmaninkatu 4, SF-00290 Helsinki, Finland

Some previous studies have shown remarkably high finger doses to radiologists performing percutaneous drainage under fluoroscopy. To assess the possible need for extra finger dosemeters in addition to the general dosemeter, radiologists' and assistants' radiation exposure at both shoulders and at the third fingers of both hands were recorded using thermoluminescent dosemeters during 27 interventional drainage procedures. Under couch screening was used. Mean dose rates were calculated by dividing the doses by the screening time. The dose rates for the sites measured were correlated with each other. The radiologists' bilateral finger dose rates did not correlate with each other; nor did dose rates between the left shoulder and the right hand. The radiologists' dose rates at both shoulders, however, correlated with each other, as did the shoulder dose rates with the dose rates athe ispilateral hand. The right shoulder dose rates correlated with the left hand dose rates. The assistants' dose rates at the places of measurement all showed significant correlations with each other. It is therefore concluded that radiologists involved in percutaneous drainages should use finger dosemeters on both hands; for assistants this may not be necessary.

Key Words: Dosimetry • Interventional radiology • Occupational safety • Percutaneous drainage • Radiation monitoring

Received for publication February 20, 1992. Revision received June 11, 1992. Accepted for publication June 29, 1992.