BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1992) 65, 686-690
© 1992 British Institute of Radiology
doi: 10.1259/0007-1285-65-776-686

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kotre, C. J.
Right arrow Articles by Faulkner, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kotre, C. J.
Right arrow Articles by Faulkner, K.

An alternative approach to contrast-detail testing of X-ray image intensifier systems

C. J. Kotre, MSc, ACGI N. W. Marshall, BSc, ARCS and K. Faulkner, PhD, ARCS

Regional Medical Physics Department, Newcastle General Hospital, Newcastle-upon-Tyne NE4 6BE, UK

The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed.

Key Words: Fluoroscopy • Image quality • Quality assurance

Received for publication June 26, 1991. Revision received November 14, 1991. Accepted for publication January 14, 1992.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
D S Evans, A Mackenzie, C P Lawinski, and D Smith
Threshold contrast detail detectability curves for fluoroscopy and digital acquisition using modern image intensifier systems
Br. J. Radiol., September 1, 2004; 77(921): 751 - 758.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D J Gallacher, A Mackenzie, S Batchelor, J Lynch, and J E Saunders
Use of a quality index in threshold contrast detail detection measurements in television fluoroscopy
Br. J. Radiol., July 1, 2003; 76(907): 464 - 472.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. B. Peter, W. Pavlicek, and J. M. Owen
Soft-Copy Quality Control of Digital Spot Images Obtained by Using X-ray Image Intensifiers
Radiology, September 1, 2000; 216(3): 810 - 819.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1992 by the British Institute of Radiology.