Departments of Radiology and Surgery, Nuffield Orthopaedic Centre NHS Trust, Windmill Road, Headington, Oxford OX3 7LD, UK
The distraction gap at eight sites in six patients undergoing limb lengthening was monitored by both standard radiographs and ultrasound. Using the measurements obtained we were able to assess the rate and quality of callus formation at the distraction site, something that radiographs alone do not enable one to do. We suggest that ultrasound has a valuable role to play in gauging the optimum rate of lengthening for a particular patient and commend it as a technique to complement radiographs in the follow-up of the increasing numbers of patients undergoing distraction osteogenesis.
Key Words: Ultrasound Limb lengthening Callotasis
This article has been cited by other articles:
![]() |
H Selim, N Elbargothy, Y Nabil, and I El-Hakim Evaluation of distracted mandibular bone using computed tomography scan and ultrasonography: technical note Dentomaxillofac. Radiol., July 1, 2009; 38(5): 274 - 280. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. B. Weiss, J. A. Jacobson, and M. A. Karunakar The Use of Ultrasound in Evaluating Orthopaedic Trauma Patients J. Am. Acad. Ortho. Surg., December 1, 2005; 13(8): 525 - 533. [Abstract] [Full Text] [PDF] |
||||