BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1990) 63, 934-939
© 1990 British Institute of Radiology
doi: 10.1259/0007-1285-63-756-934

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davies, A. M.
Right arrow Articles by Wellings, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davies, A. M.
Right arrow Articles by Wellings, R. M.

Real-time digital contrast enhancement and magnification in the assessment of scaphoid and other wrist injuries

A. M. Davies, FRCR * E. Morris, FRCR R. A. Manns, FRCR J. Fowler, MB, ChB and R. M. Wellings, FRCS

Department of Radiology, Birmingham General Hospital, Steelhouse Lane, Birmingham B4 6NH

Correspondence: * Author for correspondence.

A study on the value of a commercially available desk-top digital magnifier–contrast enhancer (DETECT System) was made in a series of 550 patients presenting with an acute wrist injury. Four radiologists, of varying experience, independently reviewed the radiographs on a conventional lightbox and later with the digitizer. In the scaphoid series (350 cases), the performance of the two more experienced radiologists was marginally better with the digitizer, whereas the less experienced radiologists performed slightly worse. Overall the digitizer improved the confidence of the radiologists in diagnosing correctly the presence of a scaphoid fracture but, for the less experienced radiologists, this was at the expense of identifying normality. In the wrist series (200 cases), the use of the digitizer resulted in a minor increase in the true positive and decrease in the false negative observations, but this was offset by a concomitant minor increase in the false positive and decrease in the true negative categories. Evaluation of the soft-tissue planes around the wrist joint showed a limited value in the identification of a scaphoid fracture with an overall positive predictive value of 0.26. Correlation of soft-tissue changes and the presence or absence of a scaphoid fracture was slightly worse with the digitizer. Possible causes for the apparently poorer performance of the digitizer are discussed, as well as the relative merits and potential value of the unit.

Received for publication June 1, 1990. Revision received July 1, 1990.