BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1989) 62, 817-823
© 1989 British Institute of Radiology
doi: 10.1259/0007-1285-62-741-817

This Article
Right arrow Full Text (PDF)
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Warren, R. C.
Right arrow Articles by Darwin, C. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Warren, R. C.
Right arrow Articles by Darwin, C. J.

Assessment of feature size abnormalities using receiver operating characteristic analysis

R. C. Warren, PhD, CPhys, MInstP and C. J. Darwin, BSc *

Department of Medical Physics and Bioengineering, University College and Middlesex School of Medicine, Shropshire House, 11–20 Capper Street, London WC1E 6JA * Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT

The ability of an observer to detect variations in size of a geometrical image feature have been investigated using receiver operating characteristic (ROC) analysis. Three types of image were constructed using computer graphics: disc-shaped targets of variable radius, model chest radiographs showing a variable heart diameter and model arterial angiograms with variable vessel width. Five factors were investigated: observer experience, variation of detectability with theoretical signal-to-noise ratio, the prior probability of the presence of an abnormality, viewing distance, and uncertainty in the location of an abnormality. In all but one experiment, excellent agreement was found between measured detectabilities and the predictions of signal detection theory, providing an initial practice session was included for each observer. No significant variation in detectability was found using six different prior probabilities and two different viewing distances, and the reduction in detectability for a four-alternative location task was in good agreement with theoretical predictions. The high statistical efficiencies found for the detection of geometrical signals suggest that the levels of observer "internal" noise arising from decision-making processes during an ROC experiment are very low.

Received for publication July 1, 1988. Revision received March 1, 1989.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1989 by the British Institute of Radiology.