A balanced valve amplifier is described for use with a graphite ionisation chamber of 3 c.mm. volume.
Measurements were made of the intensity distribution at distances between 3 mm. and 15 mm. from the centre of radium preparations.
The results indicate that the simple Sievert formulæ for intensity distribution are, to a close approximation, applicable.
Received for publication February 10, 1933.