BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1986) 59, 209-215
© 1986 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Crean, P. A.
Right arrow Articles by Maseri, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Crean, P. A.
Right arrow Articles by Maseri, A.

The British Journal of Radiology, Vol 59, Issue 699 209-215, Copyright © 1986 by British Institute of Radiology


ARTICLES

The fractional distribution of the cardiac output in man using microspheres labelled with technetium 99m

PA Crean, T Pratt, GJ Davies, M Myers, P Lavender and A Maseri

To investigate the distribution of organ blood flow in patients we have developed a method of quantitating the whole-body fractional distribution of 99Tcm-labelled microspheres. The microspheres were injected into the left ventricle in nine patients with normal cardiac indices (greater than 3 1/min/m2; Group A) and 11 patients with low cardiac indices (less than 2.51 l/min/m2; Group B). The fractional organ content of the total injected dose was estimated following correction for geometry and transmission using a gamma camera. Cerebral blood flow was 579 +/- 163 ml/min (mean +/- SD) in Group A and 593 +/- 158 ml/min in Group B (p not significant (NS)). Myocardial flow in Group A was 266 +/- 82 ml/min and in Group B was 237 +/- 57 ml/min (p, NS). Total renal blood flow was 749 +/- 161 ml/min in Group A and 614 +/- 181 ml/min in Group B (p less than 0.01). There was a negative correlation between cardiac index and the percentage of the cardiac output distributed to brain (r = -0.70, p less than 0.01), heart (r = -0.67, p less than 0.01) and kidneys (r = -0.47), p less than 0.05). Low output cardiac failure is, therefore, associated with relative preservation of cerebral and myocardial blood flow and, to a lesser extent, of renal flow. A similar technique using dual labelling would allow an accurate estimation in individual patients, of the change in organ blood flow associated with transient alterations in cardiac output states.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1986 by the British Institute of Radiology.