BJR
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

British Journal of Radiology (1982) 55, 60-69
© 1982 British Institute of Radiology
doi:

Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shope, T. B.
Right arrow Articles by Speller, R. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shope, T. B.
Right arrow Articles by Speller, R. D.

The British Journal of Radiology, Vol 55, Issue 649 60-69, Copyright © 1982 by British Institute of Radiology


ARTICLES

Radiation dosimetry survey of computed tomography systems from ten manufacturers

TB Shope, TJ Morgan, CK Showalter, KS Pentlow, LN Rothenberg, DR White and RD Speller

Profiles of the absorbed dose delivered throughout cylindrical and anthropomorphic phantoms during single scans by computed tomography systems from ten manufacturers were measured using LiF thermoluminescent dosemeters (TLD) and X-ray therapy verification film. The dose profiles demonstrate that a significant portion of the dose is delivered outside the imaged volume of a single scan. The doses measured in cylindrical Plexiglas phantoms were similar to those measured in anthropomorphic cross sections of tissue substitute materials except near the centre of the thorax section. The film results, obtained using a single calibration curve, agreed with the TLD results to within 25% for most systems.


This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
L. W. Goldman
Principles of CT: Radiation Dose and Image Quality
J. Nucl. Med. Technol., December 1, 2007; 35(4): 213 - 225.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
I. A. Castellano, D. R. Dance, and P. M. Evans
CT dosimetry: getting the best from the adult Cristy phantom
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 321 - 325.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P Aviles Lucas, I A Castellano, D R Dance, and E Vano Carruana
Analysis of surface dose variation in CT procedures
Br. J. Radiol., December 1, 2001; 74(888): 1128 - 1136.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
V Tsapaki, S Kottou, and D Papadimitriou
Application of European Commission reference dose levels in CT examinations in Crete, Greece
Br. J. Radiol., September 1, 2001; 74(885): 836 - 840.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. Liu, S. J. Esler, B. J. Kenny, R. H. Goh, A. J. Rainbow, and G. W. Stevenson
Low-Dose Nonenhanced Helical CT of Renal Colic: Assessment of Ureteric Stone Detection and Measurement of Effective Dose Equivalent
Radiology, April 1, 2000; 215(1): 51 - 54.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
BJR DMFR IMAGING  ALL BIR JOURNALS 
Copyright © 1982 by the British Institute of Radiology.